T-Modul

signal conditionning electronic for halfbridge transducers, mountable into frontpanels, output signal +/- 10 or +/- 5 VCD, for full specification displacment for the transducer

application

signal conditionning for T-series transducers
for TESA® compatible halfbridge transducers

dimension

31 x 50 mm (no casing)

fixing

with threaded ring, hole diameter for socket fixing 18 mm

supply voltage

supply voltage 5, 12 or 24 VDC (+/- 10%) (please specify with order)
current consumption 120, 50 or 25 mA

signal output

+/- 10 VDC for tranducers
T101/T102, measuring stroke +/- 1 mm
T201/T202, measuring stroke +/- 1 mm
T301/T302, measuring stroke +/- 2 mm
T401/T402, measuring stroke +/- 1 mm
T501/T502, measuring stroke +/- 5 mm (for setting 1:5)
T521/T522, measuring stroke +/- 2 mm
T523/T524, measuring stroke +/- 1 mm

+/- 5 VDC for tranducers
T501/T502, measuring stroke +/- 5 mm (for setting 1:10)

other specifications upon request

connection

supply and signal: pads on PCB
transducer: socket 5 pin, 270°

transducer supply

3 V +/- 0.5% RSM / 13 kHz +/- 5%

sensitivity

73.75 mV/(Vmm) (into R = 2 kOhm +/- 0.1%)

examples for ordering

T-module with 12 V supply voltage, signal output +/- 10 V, measuring stroke +/- 1 mm,  for a T101: TMOD12V +/-10V +/-1mm (T101)
T-module with 24 V supply voltage, signal output 0-10 V, measuring stroke +/- 5 mm,  for a T501 (with setting 1:10): TMOD24V 0-10V +/-5mm (T501, 1:10)